Skip to main content

Table 4 Polysomnographic data

From: Three-dimensional analysis of changes in airway space after bimaxillary orthognathic surgery with maxillomandibular setback and their association with obstructive sleep apnea

  T0 T1  
AHI (total) 2.24 ± 1.24 4.75 ± 5.91 p> 0.05
(Paired t-test)
AHI (supine) 2.45 ± 1.48 5.37 ± 6.31
AHI (non-supine) 1.55 ± 1.81 1.01 ± 1.53
Lowest oxygen saturation 93.92 ± 2.60 93.38 ± 5.36
  1. T0 before surgery, T1 7 months after surgery
  2. Data are shown as mean ± SD (range)