Skip to main content

Table 1 Patients and materials

From: Repeated failure of implants at the same site: a retrospective clinical study

  Age Position 1st implant 2nd implant 3rd implant
M1 74 #11 TiUnite (4×11.5) Osstem US II
M2 43 #46 Superline (5×8) Superline (7×8) Superline (5×10)
M3 68 #46 Superline (4.8×12) SinusQuick IS (5×11.5) Superline (7×10)
M4 61 #26 Osstem US III (5×11.5) Osstem US III (4×11.5) Osstem TS III BIOSA (5×11.5)
M5 62 #25 3-I Osseotite NT (5×13) 3-I Osseotite NT (5×15) Osstem US II (5×18)
M5 62 #26 3-I Osseotite NT (5×11.5) 3-I Osseotite NT (6×13) Osstem US II (5×18)
F1 66 #11 3-I Osseotite External (5×11.5) Osstem US II (4×13)
M6 57 #26 3-I EB (5×14) Superline (7×8) Superline (4.5×8)
M7 70 #26 Superline (5×14) Superline (7×10) Superline (7×12)
M8 64 #26 3I Osseotite certain Osstem US II (5×15)
M9 63 #26 Osstem TS III HA (5×10) Superline (4.8×12) Osstem TS IV (5×11.5)
M9 63 #27 Osstem TS III HA (5×10) Superline (5×15) Osstem TS IV (4.5×10)-
F2 62 #27 3-I NanoTite external (5×10) Superline (6×10) Superline (5×10)
M10 47 #15 Superline (4.3×10) Superline (4.8×14) Superline (4.8×12)
  1. M male, F female
  2. M5 and M9 repeatedly failed at two sites each